Step 5 · Determine Winder Tread Layout
This is the most critical step for winder stairs. The layout involves creating a series of angled lines that represent the edge of each winder tread. The narrowest point of the winder tread (at the inside of the turn) must be at least 6 inches wide to meet code. The widest point (at the outside of the turn) will be determined by the overall stair width and the angle of the turn. Use geometry and precise measurements to ensure the tread's 'walking line' (typically 12 inches from the outer edge) has the required depth and that the tread is not excessively tapered. This often involves using a compass or string to draw arcs at the inner and outer edges of the turn.