Step 3 · Determine Tread Depth and Landing Dimensions
Using the total run available and the number of treads, calculate the nominal tread depth. Ensure this depth, when combined with the riser height, meets the '2R + T' rule (twice the rise plus the tread depth should be between 24 and 25 inches) for comfortable and safe walking. If a landing is required, ensure its dimensions meet code (typically at least as wide as the stair and as deep as the stair's run).