Skip to main content

Inspect Commercial Stair Handrails — Inspect Handrails

Beginner4 hours

Part of project

How to Check Your Stairs Against Building Code · Step 7 of 10

Helpful?

In this video

Assess handrails on stairs within commercial buildings and spaces with public access for specific code requirements. Handrails must be present on both sides of the stair. Measure the height from a stair point to the top of the handrail: the minimum height is 34 inches (864mm), and the maximum is 38 inches (965mm). Additionally, the handrail must end above the strike point (as defined in Step 3), and it must extend 12 inches (305mm) horizontally past the top stair point. Utilize your tape measure to confirm all these dimensional and placement requirements.

4.2K views52
Transcript
Hide

three or more steps for commercial buildings and spaces with public access handrails must be on both sides of the stair measuring from a stair point to the top of a handrail the minimum Heights is 34 inches and the maximum is 38 inches the handrail must end above the strike point the tape measure can be used to show the location of the strike point to verify the handrail is long enough as it is demonstrated by the picture below the handrail must extend 12 inches horizontally past the top stair point