Step 4 · Install new 3-way switches
At the first switch location, connect the incoming hot (LINE) wire to the 'common' terminal (usually black or a different color screw). Connect the two 'traveler' wires to the two 'traveler' terminals (usually brass screws). At the second switch location, connect the wire coming from the first switch's traveler terminals to the traveler terminals on this switch. Connect the wire going to the light fixture (LOAD) to the 'common' terminal of this switch.