Step 4 · Check for Plumb and Level of Treads and Risers
Place a long level across the width of each tread to check if it is level from side to side and front to back. Then, use a level or a plumb bob to check if the vertical face of each riser is plumb (perfectly vertical). Any significant deviations from level or plumb indicate that the stairs may have settled unevenly or were not constructed correctly.