Step 9 · Test Capacitors (Advanced)

Ensure power is OFF and has been discharged from capacitors. Discharge any capacitor by shorting its terminals with an insulated screwdriver. Set your multimeter to the capacitance testing setting (usually marked with 'uF' or a capacitor symbol). Carefully remove the wires from the capacitor terminals, noting their positions. Connect the multimeter probes to the capacitor terminals as per your multimeter's instructions. Read the capacitance value and compare it to the rating printed on the capacitor. If the reading is significantly lower than the rating, the capacitor likely needs replacement.

Stesso home
SearchSearchBrowseBrowseMy ProjectsMy Projects
Log inLog inSign upSign up

Step 9 · Test Capacitors (Advanced)

Ensure power is OFF and has been discharged from capacitors. Discharge any capacitor by shorting its terminals with an insulated screwdriver. Set your multimeter to the capacitance testing setting (usually marked with 'uF' or a capacitor symbol). Carefully remove the wires from the capacitor terminals, noting their positions. Connect the multimeter probes to the capacitor terminals as per your multimeter's instructions. Read the capacitance value and compare it to the rating printed on the capacitor. If the reading is significantly lower than the rating, the capacitor likely needs replacement.

Videos for this step

Discharge and Test Capacitor with MultimeterTest Capacitor CapacitanceSafely Inspect and Test the Capacitor

Tools and Materials

← Project

Heat Pump Repair

Step 9 of 10·35 min left

Safety First: Disconnect Power
15 minutes2 items
Inspect Outdoor Unit for Visible Damage
20 minutes3 items
Check Air Filter and Indoor Unit
15 minutes3 items
Listen for Unusual Noises
10 minutes2 items
Check Refrigerant Lines for Ice Buildup
10 minutes2 items
Verify Thermostat Settings
5 minutes1 items
Inspect Condensate Drain Line for Clogs
30 minutes4 items
Check Electrical Connections (Advanced)
45 minutes4 items
9
Test Capacitors (Advanced)
30 minutes3 items
10
When to Call a Professional
5 minutes1 items