Professional Start-Up and System Testing — Perform System Startup and Initial Checks

Beginner

Part of project

Professional Installation Recommendation · Step 5 of 5

Helpful?

In this video

A certified AC technician arrives to perform the final steps. He evacuates the refrigerant lines to remove any air and moisture, then performs a leak test using a soap solution at all connections. Once the lines are proven to be leak-free, the technician opens the service valves on the outdoor unit to release the pre-charged refrigerant into the system. The system is then powered on, and the technician checks operating pressures and temperatures. The creator tests the remote control and wired thermostat, confirming all functions work. He also tests the float switch (installed in the air handler and drain pan) to ensure it shuts down the system in case of a condensate overflow. Finally, he demonstrates the strong airflow from the indoor vents and confirms the cooling and heating functions are operational.

336.6K views6.2K
Transcript
Hide

so this morning I have the AC guy coming it is recommended on the system both indoor and outdoor that you get a certified technician to come out and start the system up to avoid any delays I have everything open for quick access the outdoor unit require a minimum of 40 amps and that's in place so Mark is here again and he's doing all of his setup the first thing he did was to put pressure on the line and make sure there was no leak he's also doing a soap test to make sure there are no issues at the connectors also pretty big relief for me to not see any bubbles forming up at the connection the indoor connection was tested as well with no issue shown so so far so good the line's been tested for leaks and that pass now it's on to vacuuming should do it pretty quick because it's a short yeah it's just the the EV coil and looks like we have a green light on everything all the test was passed and since the unit comes pre-charged with the correct gas all you have to do is open up the valves equalizing out really nice let it let it keep steady with the successful system installed I can move on to putting on the final touches like wrapping the copper lines up I sleeve the copper and put black tape on the joints pan in an old video of mine I once showed how to make this contraption not identical but very similar the idea is to put a cut off valve in between the drain and the air handler once the valve is set off I can then pump water through the line and clear it out quickly before I glued the parts I tested the drain made sure it work and then I finalized it I put a float switch at the unit and also a float switch on the pan the unit comes with this portable remote so you can adjust the system from your couch or wherever within range after the system was powered up we went through a range of testing we tested a float switch to make sure that shut the system down in case of a clog to prevent any flooding we also tested the temperature coming out of the unit which we saw a 20% differential air going in versus air coming out we tested the heating and the cooling there are some things I'm still learning about this system which is why I don't want to put my thermostat in there just yet as of now between the Wi-Fi thermostat I have and this system I don't know what possible features may or may not work like the variable fan speeds or the variable modes on the thermostat that came with this system going from a person that never installed one of these system to now having…

Auto-generated transcript. May contain errors.