Skip to main content

Calculate Stair Headroom Clearance — Identify Staircase Start and End Points

Beginner2 hours

Part of project

How to Measure Stair Headroom · Step 1 of 5

Helpful?

In this video

The builder emphasizes the importance of checking local building codes for stair headroom requirements, as these can vary by location. In his specific area, a minimum of 80 inches (6 feet 8 inches) of finished headroom clearance is required from the nosing of any stair tread to the ceiling or any overhead obstruction. He demonstrates this by taking a measurement from the finished concrete floor (which will serve as the finished floor of the basement) to the underside of the floor joists/girder directly above where the stairs will ascend. This initial measurement helps identify potential conflict points and ensures the new stair opening design accounts for this critical code requirement.

9.6K views414