Step 4 · Install Bypass Valve and Fittings

This is the step most people slow down on. Take it one move at a time — there’s no rush, and you can rewind the clip as many times as you need.

This step involves creating the plumbing assembly that diverts water to and from the softener. First, clean the outside ends of the cut main line and the inside of two 90-degree copper elbows using sandpaper or a wire brush. Apply a thin layer of flux to all cleaned surfaces. Fit the elbows onto the pipe ends, pointing them towards the location of the softener. Using a soldering torch, heat the joints evenly. Once hot enough, touch the lead-free solder to the seam; it will melt and be drawn into the joint. Allow the joints to cool completely. Next, attach the bypass valve assembly that came with your softener to the two new pipes leading from the elbows, following the manufacturer's instructions. This may involve soldering on threaded adapters and then using pipe wrenches to tighten the valve connections.

Stesso home
SearchSearchBrowseBrowseMy ProjectsMy Projects
Log inLog inSign upSign up

Step 4 · Install Bypass Valve and Fittings

This is the step most people slow down on. Take it one move at a time — there’s no rush, and you can rewind the clip as many times as you need.

This step involves creating the plumbing assembly that diverts water to and from the softener. First, clean the outside ends of the cut main line and the inside of two 90-degree copper elbows using sandpaper or a wire brush. Apply a thin layer of flux to all cleaned surfaces. Fit the elbows onto the pipe ends, pointing them towards the location of the softener. Using a soldering torch, heat the joints evenly. Once hot enough, touch the lead-free solder to the seam; it will melt and be drawn into the joint. Allow the joints to cool completely. Next, attach the bypass valve assembly that came with your softener to the two new pipes leading from the elbows, following the manufacturer's instructions. This may involve soldering on threaded adapters and then using pipe wrenches to tighten the valve connections.

Videos for this step

Install Inlet & Outlet PlumbingSoldering the New Moen ValveMeasure and Prepare for Valve Installation

Tools and Materials

← Project

How to Install a Whole-House Water Softener

Step 4 of 9·1.6 hr left

Choose the Installation Location
30 mins3 itemsBeginner
Shut Off Water and Power
20 mins4 itemsBeginner
Cut the Main Water Line
30 mins3 itemsAdvanced
4
Install Bypass Valve and Fittings
1 min11 items
5
Connect the Softener to the Bypass
1 min11 itemsAdvanced
6
Install Drain and Overflow Hoses
30 mins5 itemsBeginner
7
Turn on Water and Check for Leaks
30 mins1 itemsIntermediate
8
Set Up and Program the Softener
30 mins3 itemsIntermediate
9
Run a Manual Regeneration Cycle
2 mins3 itemsBeginner