Step 3 · Testing the Heating Element (Electric Water Heaters)

This is the step most people slow down on. Take it one move at a time — there’s no rush, and you can rewind the clip as many times as you need.

For electric water heaters, use a multimeter to test the heating element's resistance. Set your multimeter to ohms and measure the resistance across the element's terminals. A reading between 10 and 30 ohms (typically around 12, 16, or 18 ohms) indicates a functional element; an 'OL' (open line) reading suggests a faulty element requiring replacement.

Stesso home
SearchSearchBrowseBrowseMy ProjectsMy Projects
Log inLog inSign upSign up

Step 3 · Testing the Heating Element (Electric Water Heaters)

This is the step most people slow down on. Take it one move at a time — there’s no rush, and you can rewind the clip as many times as you need.

For electric water heaters, use a multimeter to test the heating element's resistance. Set your multimeter to ohms and measure the resistance across the element's terminals. A reading between 10 and 30 ohms (typically around 12, 16, or 18 ohms) indicates a functional element; an 'OL' (open line) reading suggests a faulty element requiring replacement.

Videos for this step

Check Elements (Continuity)Test for a ShortInterpret the Reading

Tools and Materials

← Project

Troubleshooting No Hot Water: Fixing Your Water Heater

Step 3 of 3·30 min left

Safety First: Turn Off Power and Water
5 minsBeginner
Inspect the Water Heater Thermostat
5 minsBeginner
3
Testing the Heating Element (Electric Water Heaters)
30 mins1 itemsAdvanced